Catalogue RJ Field BR - page 37

37
Amphenol
RJF TV
Hermetic receptacles
Part number code
Series
RJFTV
:
MIL-DTL-38999 series III
RJF TV
7H
A
2
G
03 100BTX
Shell type
2H
:
transversally sealed and hermetic square flange receptacle
7H
:
transversally sealed and hermetic jam nut receptacle
Coding
A,B,C,D
Back terminations
(for receptacles only)
1
:
female RJ45
1RA
:
right angle female RJ45
2
:
RJ45 Cordset
Shell material & finish
N
:
aluminium shell - nickel plating -
ROHS compliant
G
:
aluminium shell - olive drab cadmium plating
BZ
:
marine bronze shell -
ROHS compliant
Nota
: receptacle inserts are metallized
BZC
:
aluminium shell - black zinc cobalt plating -
ROHS compliant
ZC
:
aluminium shell - green zinc cobalt plating -
ROHS compliant
ZN
:
aluminium shell - black zinc nickel plating -
ROHS compliant
Cordset length
(for receptacles with “2” back termination only)
- Other lengths are available on demand
03 100 BTX
:
0.3m [11.81 inches]
05 100 BTX
:
0.5m [19.68 inches]
10 100 BTX
:
1m [39.37 inches]
15 100 BTX
:
1.5m [59.05 inches]
xx OPEN
: open cable - with no plug at the end (
xx
to be replaced by the cordset length 03, 05, 10, or 15 - see above)
Remark: cabling configuration:
100 BTX = 568B (Ethernet specification)
Examples:
- Series III, sealed jam nut receptacle, A coding, with female RJ45 Back termination, olive drab cadmium plating:
RJF TV 7HA 1 G
- Series III, sealed jam nut receptacle, A coding, 1.5m [59.05”] 100 BTX cordset, olive drab cadmium plating :
RJF TV 7HA 2 G15 100BTX
In some applications, a transversal hermiticity for the receptacle is a «
must ».
This will prevent gas from going through the receptacle when plug or
cap are not mated to the receptacle.
The hermetic solution (version "H") has a compound at the rear of the
receptacle as shown on the picture.
Helium leakage is less than 1.10
-6
cm
3
per second [0.1 micron cubic ft
per hour] at one bar [15 psi] pressure differential.
compliant
ROHS
N, B
&
BZ
Data transmission
10 BaseT, 100 BaseTX and 1000 BaseT networks
Cat 5e per TIA/EIA 568B and ClassD per ISO/IEC
11801
Applications
n
Outdoor equipment
n
Airplanes equipment
n
Tactical radios
n
Shelters
n
Rugged computers
n
Data acquisition and transmission in harsh
environments
Main characteristics
n
Same as the RJF TV series.
n
A complete IP68 sealing of the receptacle (even with no plug or no
protective cap mated) is added.
n
Outside dimensions are the same as the standard RJF TV series.
n
Vibrations: the compounded versions of the RJF TV have been tested in
vibration following the NAS 1599 Aeronautic specification (Ambient tem-
perature):
5 - 3000 Hz, 20g, 2,5 mm [.1 inch] double amplitude, 3 axes, 12 hours
Note: this specification exceeds MIL-C-26500 requirements.
RJFTV 2H
A
2 N 15 100BTX
Example :
IMPORTANT NOTE
Due to the compound, the coding of the connector must be done in the factory: use the
codes A, B, C or D in the part number:
see below
.
Receptacle
Main key
Coding A Coding B Coding C Coding D
1...,27,28,29,30,31,32,33,34,35,36 38,39,40,41,42,43,44,45,46,47,...156
Powered by FlippingBook