Catalogue RJ Field HD - page 114

Amphenol
114
USBBF TV
(USB-B)
USB connection system for harsh environment
compliant
ROHS
N
Applications
n
Embedded Computers
n
Data Acquisition and transmission in harsh
environment
n
Railways
n
Battelfield Communication Systems
n
Navy Systems
USB Field allows you to use a standard USB 2.0 connection in harsh
environment:
• sealed against fluids and dusts (IP68)
• shock, vibration and traction resistant
• no cabling operation in field and no tools required
• improved EMI protection
• Tri Start thread coupling mechanism (MIL-DTL-38999 series III type)
with anti-decoupling device
• plug retention in the receptacle: 100N in the axis
• mating cycles: 500 minimum
• temperature range: -40°C/+85°C
Part number code
Series
USBB Field TV
USBBF TV
2
1
G
Shell type
6
:
plug
2
:
square flange receptacle
2PE
:
square flange receptacle with metal backshell
(type 1)
& with metal backshell + plastic gland
(type 2)
2PEM
:
square flange receptacle metal gland (only for soldering back termination type 2)
7
:
jam nut receptacle
7PE
:
jam nut receptacle with metal backshell
(type 1)
& with metal backshell + plastic gland
(type 2)
7PEM
:
jam nut receptacle metal gland (only for soldering back termination type 2)
Back terminations
(receptacles only)
1
:
female USB-A
2
:
solder (4 tinned holes)
Shells material & finish
N
:
aluminium shell - nickel plating -
ROHS compliant
G
:
aluminium shell - olive drab cadmium plating
ZN
:
aluminium shell - black zinc nickel plating -
ROHS compliant
Examples:
- Plug-cadmium plating: USBBF TV 6G
- Square flange receptacle-USB-A back termination - cadmium plating: USBBF TV 21G
- Jam nut receptacle, solder termination -nickel plating: USBBF TV 72N
Type
2
: solder (4 tinned holes)
Type
1
: female USB-A
Data transmission
USB specification 2.0
Data rate: up to 480 Mb/s for high speed USB
Back terminations
Hole n°1
Hole n°4
Grounding
Main characteristics
n
Sealed against fluids and dusts (IP68)
n
Shock, vibration and traction resistant
n
No cabling operation in field and no tools required
n
Improved EMI protection
n
Tri Start Thread coupling mechanism (MIL-DTL-38999 series III type) with
anti-decoupling device - Shell size 15
n
Plug retention in the receptacle: 100N in the axis
n
Mating cycles: 500 minimum
Environmental protection
n
Sealed against fluids and dusts (IP68)
n
Temperature range: - 40°C / +85°C