Page 1 - fiche SLR VA

SEO Version

DESCRIP
APPLICATIONS
applications in harsh environment
(Shocks, Vibrations, Humidity) like
shelters, off shore or buiding sites
activities
Coding by user allows a diminutio
the number of references to mana
Shelters
Power
Check-Control
Building sites
Off shore
MAIN CHA
backshell with cable clamp and sealing gland backshell.
Metallic protective caps for plug and receptacle with seal.
Working temperature: -55°C/+125°C.
5 positionning keys for Plug / Receptacle.
Coding by the user: 12 coding possibilities (from A to M) by insert rotation.
(without any specific tool).
Crimp removable gold plated machined contacts
Closed entry female contacts.
3 arrangements: 55 size 16 contacts, 37 size 12 contacts, 37 size 16 contacts.
For other arrangement, please consult us.
E105/A
SLR : Harsh
environment ju
make it strong
General characteristics:
CHARACTERISTIC
VALUE
NORME
Watertightness
IP67 connected
NFEN 60 529
Physical shock
IK06 / 1.5 kg mass dropped from a 40 cm NFEN 50 102
height
Fall test
Fall Height: 1 meter
NFC 93 400 - Test 7b
Vibrations
10 to 60 Hz,
amplitude 0.075 mm
60 to 100 Hz, no cut
1µs
NFC 93 400 - Test 6b
speed 25.4 mm/sec
100 to 600 Hz,
acceleration 5G
Cable clamp tensile strength 40 kg in axis
NFC 93 400 - Test 17c
Acceptable cables
20 to 35 mm
diameter:
Humidity
21 days - 43°C to humidity 98%
NFC 93 400 - Test 11c
Working temperature
-55°C/+125°C
NFC 93 400 - Test 11d
Durability
100 mating cycles
NFC 93 400 - Test 9a
Proof voltage
3000 V
NFC 93 400 - Test 4a
Insert resistance
100 M
NFC 93400 - Test 3a
Contact resistance
2 m
NFC 93400 - Test 2a-2b
Note: Reference document NFF 61-030
UL 1977 approved