技術情報
- 以下のイーサネットプロトコルをサポート10/100/1000/10GBase-Tイーサネット
ドキュメント
よくあるご質問
コンタクト
高速コンタクト
<p>The manufacturer is identified on the contact using a “MINT” mark. This mark is recorded in a certification organization and is unique per manufacturer. For Amphenol Socapex, the mint mark is ||.</p>
<p>Our <a href="/products/contacts/signal-contacts/en3155-signal-contacts" target="_blank">EN3155 contacts</a> are all manufactured in Thyez, France in our dedicated Contacts workshop.<o:p></o:p></p>
<p>Yes there is two lengths for socket contacts because of the connector cavities:</p>
<ul>
<li>M39029/57 and EN3155-003 for MIL-DTL-38999 series II, EN4165 and 2M</li>
<li>M39029/56 and EN3155-009 for MIL-DTL-38999 series I and III and EN364.</li>
<li><a href="/faq?facets_query" target="_blank">What is the meaning of the color bands on standardized contacts ?</a></li>
<li>The color bands are marked on the contact to permit the identification of them.<br>For AS39029 contacts, there are 3 colors bands called “BIN” code (for Basic Identification Number). Please refer to the below chart to determine the BIN code.</li>
</ul>
<article class="align-center">
<img width="555" height="81" alt="color brands contacts contact" loading="lazy" class="lazyload" data-src="/sites/default/files/styles/optimized/public/media/image/2024-02/contact.png?itok=3TpIC9Hy">
</article>
<p> </p>
<article>
<img width="315" height="95" alt="contact bin code" loading="lazy" class="lazyload" data-src="/sites/default/files/styles/optimized/public/media/image/2024-02/contact_2.png?itok=my15Filt">
</article>
<p>BIN CODE = 672</p>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;">2 major standards defines the contacts for connectors, AS39029 and EN3155. There are defining dimensions and performances. SAE organization is managing AS39029 (United States) and ASD-STAN is managing EN3155 (Europe).</p>
<article class="align-center">
<img width="945" height="914" alt="standars driven contacts contact" loading="lazy" class="lazyload" data-src="/sites/default/files/styles/optimized/public/media/image/2024-02/contacts_3.png?itok=Mcs8PzbW">
</article>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;"><o:p></o:p></p>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;">Some reduced or enlarged crimping barrel designs are defined in EN3155 standard. For enlarged crimping barrels, there is some limitation on the diameter in order to allow the use of the extraction tool and to release the contact while inserted.<o:p></o:p></p>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;">American Wire Gauge is a standardized wire gauge systems defining the diameters of conductive wires. The AWG tables usually are for a single, solid and round conductor. As for the contact size, the higher the gauge or AWG number is, the smaller the wire diameter is. For example, the AWG 0000 (or 4/0) has a diameter of 11.68mm when AWG 40 has a diameter of 0.09mm.<o:p></o:p></p>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;"><span style="color:black;">The size of the contact is defined by the connector cavity and a relationship with the cable gauge (or AWG). The cable gauge defines the nominal current that the contact can accept. The contact size is identidied by a number. </span></p>
<article class="align-center">
<img width="423" height="165" alt="contacts contact size" loading="lazy" class="lazyload" data-src="/sites/default/files/styles/optimized/public/media/image/2024-02/size_contacts.png?itok=l5dCRwmO">
</article>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;"><o:p></o:p></p>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;"><o:p></o:p></p>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;"><span style="color:black;">Contacts for connectors are called PIN or SOCKET. It defines the gender of contact. </span><o:p></o:p></p>
<article>
<img width="353" height="186" alt="male contacts" loading="lazy" class="lazyload" data-src="/sites/default/files/styles/optimized/public/media/image/2024-02/pin_male.jpg?itok=WUfk0KtM">
</article>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;"><o:p></o:p></p>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;"><strong>Pin / Male Contacts </strong><o:p></o:p></p>
<article>
<img width="353" height="186" alt="female contacts contact" loading="lazy" class="lazyload" data-src="/sites/default/files/styles/optimized/public/media/image/2024-02/female_contacts.jpg?itok=ZZhlog3U">
</article>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;"><o:p></o:p></p>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;"><strong>Socket / Female Contacts</strong><o:p></o:p></p>
<p class="MsoNormal" style="line-height:normal;mso-margin-bottom-alt:auto;mso-margin-top-alt:auto;"><span style="font-family:"Times New Roman",serif;font-size:12.0pt;mso-ansi-language:EN-US;mso-fareast-font-family:"Times New Roman";mso-fareast-language:FR;" lang="EN-US"> </span><o:p></o:p></p>
関連商品
ご注文はお決まりですか?
営業担当者または代理店にお問い合わせください。
スプリットペア・クアドラックス・コンタクトの説明
スプリットペアQuadraxコンタクトは、Cat 5Eよりも高いデータレートを可能にする、より優れたクロストーク性能を提供するように設計されています。これらのコンタクトはコンタクトサイズ8で入手可能で、MIL-DTL-38999、EN3645、EN4165、およびARINC600コネクタと互換性があります。圧着タイプとPCテールタイプがあり、キー付きコンタクトに対応するため、サイズ8のキャビティを変更する必要があります。スプリットペアQuadraxコンタクトは、イーサネット、DVI、USB 2.0、HDMI 1.3a、SATA 2.0、およびUSB 2プロトコルに使用できます。これらのコンタクトは、10/100/1000/10GBase-Tイーサネットプロトコルをサポートします。スプリットペア・クアドラックス・バージョンを識別するヒントは、コンタクトの前面をチェックすることです。絶縁体が黒と白の場合、スプリットペア・クアドラックス・コンタクトです。要約すると、スプリットペア・クアドラックス・コンタクトは、従来のCat 5Eと比較して優れた性能を提供し、高速データ転送アプリケーションに最適な選択肢となります。さまざまなコネクター・タイプやプロトコルとの互換性により、汎用性があり、ユニークなデザインにより、容易に認識することができます。